Data as of: 2026-08-05 Administration DE EN
Plant Protection Product Search

« Indications · to the product

Conaxis

Use number: 00A819-00/00-004

Crops
field pea
Pests
annual dicotyledonous weeds
Area of use
Outdoors
Field of activity
Herbicide
Application technique
spraying
Growth stage
00 – 09
Applications per crop
Applications per growing season
1
authorised until
2027-09-30

Application rates

ConditionProduct rateWater rate
1.5 LH 100 – 400 LH

Pre-harvest intervals

CropPre-harvest intervalRemarksexcluded
field pea The PHI is covered by the conditions of use and/or the vegetation period remaining between the application of the plant protection product and the use of the product (e. g. harvest) or the setting of a PHI in days is not required resp.

Timing of application

Purpose of use

Restrictions

Code Text Crop Buffer zone
WH9161 The instructions for use must include a summary of weeds which can be controlled well, less well and insufficiently by the product, as well as a list of species and/or varieties showing which crops are tolerant of the intended application rate and which are not.
WH960 The risk of replanting has to be indicated on the package and in the instructions of use. Particularly the endangered succeeding crops have to be declared and measures for a risk management have to be described.
WP734 Damage is possible to the crop.
WP740 Take care of adjacent crops, since damage is possible.
WP744 Damage possible to adjacent woody plants.
NT140 Application of the product with a water application rate of less than 150 l/ha has to be conduct-ed with a field sprayer that is listed with a drift reduction class of at least 50 % in the list of "loss-reducing devices" in the first announcement on the entry of tested device types in the descrip-tive list pursuant to Section 52 (2) of the Plant Protection Act of September 10, 2013 (BAnz AT 23.10.2013 B4), as amended. The conditions of use for application with a drift reduction of at least 50 %
NW609-2 When applying the product on areas adjacent to surface waters - except only occasionally but including periodically water-bearing surface waters - the product must be applied observing the minimum buffer zone stated below. It is not necessary to observe this buffer zone if the product is applied using equipment which is registered in the index of 'Loss Reducing Equipment' of 10 September 2013 (Federal Gazette AT 23.10.2013 B4) as amended. Irrespective of this, in addition to the minimum buffer z 5 m
NW705 Between treated areas which have an incline of more than 2 % and surface waters - including periodically but excluding occasionally water-bearing surface waters - there must be a buffer zone under complete plant cover. The buffer zone's protective function must not be impaired by the use of implements. It must be at least 5 m wide. This buffer zone is not necessary if: -sufficient catching systems are available for the water and soil transported by run-off, which do not flow into surface water