« Indications · to the product
InnoProtect Pendi 400 SC
Use number: 006839-60/00-001
- Crops
- winter rye, winter soft wheat, winter barley, winter triticale
- Pests
- annual dicotyledonous weeds, ausgenommen: chamomille spec., ausgenommen: field chamomile
- Area of use
- Outdoors
- Field of activity
- Herbicide
- Application technique
- spraying
- Growth stage
- 10 – 13
- Applications per crop
- –
- Applications per growing season
- 1
- authorised until
- 2027-12-31
Application rates
| Condition | Product rate | Water rate |
|---|---|---|
| 4 LH | 200 – 400 LH |
Pre-harvest intervals
| Crop | Pre-harvest interval | Remarks | excluded |
|---|---|---|---|
| winter soft wheat | – | The PHI is covered by the conditions of use and/or the vegetation period remaining between the application of the plant protection product and the use of the product (e. g. harvest) or the setting of a PHI in days is not required resp. | – |
| winter barley | – | The PHI is covered by the conditions of use and/or the vegetation period remaining between the application of the plant protection product and the use of the product (e. g. harvest) or the setting of a PHI in days is not required resp. | – |
| winter triticale | – | The PHI is covered by the conditions of use and/or the vegetation period remaining between the application of the plant protection product and the use of the product (e. g. harvest) or the setting of a PHI in days is not required resp. | – |
| winter rye | – | The PHI is covered by the conditions of use and/or the vegetation period remaining between the application of the plant protection product and the use of the product (e. g. harvest) or the setting of a PHI in days is not required resp. | – |
Timing of application
- after emergence
- autumn
Restrictions
| Code | Text | Crop | Buffer zone |
|---|---|---|---|
| WH9161 | The instructions for use must include a summary of weeds which can be controlled well, less well and insufficiently by the product, as well as a list of species and/or varieties showing which crops are tolerant of the intended application rate and which are not. | – | – |
| WP710 | Damage is possible to replanted dicotyledonous intermediate crops and winter rape. | – | – |
| NW705 | Between treated areas which have an incline of more than 2 % and surface waters - including periodically but excluding occasionally water-bearing surface waters - there must be a buffer zone under complete plant cover. The buffer zone's protective function must not be impaired by the use of implements. It must be at least 5 m wide. This buffer zone is not necessary if: -sufficient catching systems are available for the water and soil transported by run-off, which do not flow into surface water | – | – |
| NW607-2 | When applying the product on areas adjacent to surface waters - except only occasionally but including periodically water bearing surface waters - the product must be applied with equipment which is registered in the index of 'Loss Reducing Equipment' of 10 September 2013 (Federal Gazette AT 23.10.2013 B4) as amended. Depending on the drift reduction classes for the equipment stated below, the following buffer zones must be kept from surface waters. In addition to the minimum buffer zone from su | – | – |